APM110
|
Precision load monitor
|
- Measures true power (kW)
- For fixed frequency motors (50/60Hz)
- Internal CT to 80 A, external above 80A
- Analog 4(0)-20 mA & 0-10V output
|
Plus...
|
- Digital scaling from 0.1 to 70kW
- Pulse output of kWH
|
|
|
|
|
HPL110
|
Dual Limit over/under load monitor
|
- Two programmable power limits [kW%] for
- Overload and Underload monitoring
- Single SPDT relay for alarm indication
- Start/nuisance trip delay timers
- Optional Hysteresis function for control applications
|
Plus...
|
- Remote reset, alarm blocking & peak detect
- Power down alarm inhibit
- Program locking
|
|
|
|
|
HPL110A
|
Panel Mount variant of HPL110 load monitor
|
- Two programmable power limits [kW%] for
- Overload and Underload monitoring
- Single SPDT relay for alarm indication
- Start/nuisance trip delay timers
- Optional Hysteresis function for control applications
- Panel mount enclosure
|
Plus...
|
- Remote reset, alarm blocking & peak detect
- Power down alarm inhibit
- Program locking
|
|
|
|
|
HPL130A
|
Dual limit Overload - Shockload monitor
|
- Max. limit - overload alarm, plus
- +dP/dt shockload alarm
- SPDT alarm relay for alarm indication
- Start/nuisance trip delay timers
- Optional Hysteresis function for control applications
|
Plus...
|
- Remote reset, alarm blocking & peak detect
- Analog 4-20mA output of kW[%]
- Program locking & phase error alarms
|
|
|
|
|
HPL220
|
Flexible multi-function dual limit monitor
|
- When motor power is not viable
- Uses separate sensor e.g. a load cell
- 3 signal input options incl. strain gage excitation
- Limits configurable as Max or Min
- Dual SPNC alarm relays with programmable polarity
|
Plus...
|
- Zero offset and range scaling capabilities
- 4-20 mA analog output
- Optional Hysteresis function for control applications
|
|
|
|
|
HPL410
|
Single Limit Overload or Underload monitor
|
- Single programmable power/ limit [kW%] for
- Overload or Underload monitoring
- SPDT alarm relay for alarm indication
- Optional Po idle power subtraction function
- Start/nuisance trip delay timers
- Optional Hysteresis function for control applications
|
Plus...
|
- Remote reset, alarm blocking & peak detect
- Analog 4-20mA output of kW[%]
- Program locking & phase error alarms
|
|
|
|
|
HPL420
|
Dual limit Overload - Underload monitor
|
- Two programmable power limits [kW%] for
- Overload and Underload monitoring
- Dual SPNC alarm relays with programmable polarity
- Start/nuisance trip delay timers
- Optional Hysteresis function for control applications
|
Plus...
|
- Remote reset, alarm blocking & peak detect
- Analog 4-20mA output of kW[%]
- Program locking & phase error alarms
|
|
|
|
|
HPL425
|
Dual limit Overload - Overload monitor
|
- Two programmable power limits [kW%] for
- Dual Overload monitoring - max. Lim.1 & max. Lim.2
- Dual SPNC alarm relays with programmable polarity
- Start/nuisance trip delay timers
- Optional Hysteresis function for control applications
|
Plus...
|
- Remote reset, alarm blocking & peak detect
- Analog 4-20mA output of kW[%]
- Program locking & phase error alarms
|
|
|
|
|
HPL426
|
Dual limit Overload monitor
|
- Two programmable power limits [kW%] for
- Overload monitoring of two speed motors
- Max. Lim.1 or Max. Lim.2 remote selectable
- Dual SPNC alarm relays with programmable polarity
- Start/nuisance trip delay timers
- Optional Hysteresis function for control applications
|
Plus...
|
- Remote reset, alarm blocking & peak detect
- Analog 4-20mA output of kW[%]
- Program locking & phase error alarms
|
|
|
|
|
HPL430
|
Dual limit Overload - Shockload monitor
|
- Max. limit - overload alarm, plus
- +dP/dt shockload alarm
- SPDT alarm relay for alarm indication
- Start/nuisance trip delay timers
- Optional Hysteresis function for control applications
|
Plus...
|
- Remote reset, alarm blocking & peak detect
- Analog 4-20mA output of kW[%]
- Program locking & phase error alarms
|
|
|
|
|
HPL440
|
Conveyor Overload monitor with Un-Block Function
|
- Single Max. power limit [kW%] - overload alarm with
- Motor reversal un-block function
- Two SPNC relays, one for each direction
- Indication of un-recoverable blocking condition
- Start/nuisance trip delay timers
|
Plus...
|
- Remote reset & peak detect
- Analog 4-20mA output of kW[%]
- Program locking & phase error alarms
|
|
|
|